U/UTP Category 6, 4 pairs, LSZH 305m box

Description

Description

Standards

  • International
    EN 50173-1; IEC 61156-5; ISO/IEC 11801
  • National
    ANSI/TIA-568-C.2

Application

Nexans U/UTP Category 6 cables are the mid-range 250MHz offering from Nexans. Manufactured in accordance with ISO IEC 61156-5 requirements, the U/UTP cable is the best choice to support all Class E applications like Ethernet, Fast Ethernet, Gigabit Ethernet, … The Cat 6 U/UTP cables are suitable for basic voice and data installations up to 250 MHz.

Performance

Nexans Category 6 cables are compliant with the requirements of EN 50288 and ISO IEC 61156-5 standards. Used with Cat 6 connectivity, these cables are compliant with Class E link requirements as described in EN 50173 Edition 2 and ISO 11801 Edition 2 standards(2002).

Features

  • Central cross for improved geometry and performance
  • Central cross member reduces risk of crushing or kinking
  • Compact design for minimum volume in ducts or trails.
  • LSZH sheath
  • Design for easy and quick installation
  • Solid 23 AWG cable
  • RoHS EC Directive 2002/95/EC compliant

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Type of cable
UTP
Outer sheath
LSZH
Colour
White

Dimensional characteristics

Dimensional characteristics

Approximate weight
38 kg/km
Conductor diameter
- mm
Diameter over insulation
0.97 mm
Nominal outer diameter
6.0 mm

Electrical characteristics

Electrical characteristics

Characteristic impedance
100 Ohm
Max. DC resistance of the conductor at 20°C
93.8 Ohm/km
Mutual capacitance
56 nF/km

Transmission characteristics

Transmission characteristics

Attenuation, max. 250 MHz
32.8 dB/100m
Attenuation Crosstalk Ratio, 250MHz
5.5 dB/100m
Powersum Near End Crosstalk, 250MHz
36.3 dB
Powersum Equal Level Far End Crosstalk, 250MHz
19 dB
Return loss, 250MHz
17.3 dB
Coupling attenuation at 30 MHz
45 dB
Near End Crosstalk @ 250 MHz
39.3 dB
Nominal Velocity of Propagation (NVP)
68 %
Propagation delay, max. 100 MHz
536 ns/100m
Skew
45 ns/100m

Usage characteristics

Usage characteristics

Packaging
Box
Length
305 m
Ambient installation temperature, range
0 ... 50 °C
Category
Cat. 6
Component function
Cable
Flame retardant
IEC 60332-1
Minimum dynamic operating bending radius
24.0 mm
Minimum static operating bending radius
48 mm
Operating temperature, range
-20 ... 60 °C

Resources

Resources

Documentation

xls — 0 B

Declaration of Performance

  • Declaration of Performance n� : 1000273-TRTU
  • Certification Date : 6/22/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 1783
  • Declared performance : Dca-s2,d2,a2

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close