ELAQQBEV 7x2x0,9

Description

Description

Standards

  • Test
    IEC 60332-3 Cat.C
  • National
    Customer specification

DESCRIPTION

Design

Pair-twisted, water-blocked, screened communication cable with inner and outer sheath of halogen free, flame retardant compound.  ELAQQBEV is used in communication systems for train control (ERTMS). Fire performance according to CPR class Dcas2d2a2. The cable emits no corrosive gases and has low smoke production during fire.

Quality System

Design, manufacture and testing according to the requirements in ISO 9001.

Environmental management system

The activities at our plant in Grimsås are certified to ISO 14001.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor shape
Single wired
Conductor material
Annealed copper
Insulation
Solid polyethylene
Twisted
Yes
Material used for longitudinal water tightness
Swellable yarn
Screen
Longitudinal aluminium tape
Inner sheath
LSHFFR compound
Outer sheath
LSHFFR compound
Colour
Green

Dimensional characteristics

Dimensional characteristics

Conductor diameter
0.9 mm
Number of pairs
7
Inner sheath thickness
1.2 mm
Nominal outer sheath thickness
1.5 mm
Nominal outer diameter
18.5 mm
Approximate weight
32.5 kg/100m

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
29 Ohm/km
Resistance unbalance DC max % of loop resistance
2 %
Max. capacity pair / core to core
45 nF/km
Capacitance unbalance max.
150 pF/500m
Ohmical resistance of the insulation
10000 MOhm.km
Maximum operating voltage
100 V

Usage characteristics

Usage characteristics

Packaging
K14
Length
1500 m
Ambient installation temperature, range
-15 ... 40 °C
Operating temperature, range
-25 ... 70 °C
Minimum static operating bending radius
185 mm

Resources

Resources

Documentation

xls — 0 B

Selling & delivery Information

ELAQQBEV will be delivered on drums in lengths of 500-3000m. The drum is marked with manufacturer, type of cable and length. The ends of the cable are sealed.

Declaration of Performance

  • Declaration of Performance n� : 1000610-SEGR
  • Certification Date : 7/1/19
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0366
  • Declared performance : Dca-s2,d2,a2

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close