GAHSQWQ-K-AHNRV 96/C4 G652D S12

Description

Description

Standards

  • Product
    IEC 60794
  • Test
    EN 60754-2; EN 61034; IEC 60793
  • International
    ITU-T Rec. G.652

The cable type is intended for direct burial or installation in ducts. The design incorporates 12 - 480 fibre. The fibre are grouped into ribbons consisting each of four fibre (maximum 96 fibres) or 8 fibre (maximum 480 fibre). The 4- or 8-fibre ribbon are stacked in a slotted core profile of polyethylene, which is extruded onto a dielectric fibre reinforced strength member (FRP). The cable type is longitudinal water-blocked through the use of swellable tape. It's double sheathed with halogen-free flame-retardant polymeric compound and armoured with corrugated steel tape. GAHSQWQ meets the requirements for CPR Dcas2d2a2. The cable emits no corrosive gases and has low smoke production during fire.

 

 

Quality and environmental management system

Certified according to ISO 9001, IRIS, ISO/TS 16949 and ISO 14001.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Type of secondary protection
4-fibre ribbon
Construction type
Slotted core, ribbon
Fiber optic type
SM (G.652D)
Inner sheath
HFFR (polyolefin)
Armour type
Corrugated steel
Outer sheath
HFFR (polyolefin)
Material used for longitudinal water tightness
Swellable tape
Halogen free
Yes
Metal free
No
Additional strength member
None
Number of slott
6
Sheath colour
Green
Strength member
FRP

Dimensional characteristics

Dimensional characteristics

Nominal outer diameter
16.9 mm
Number of optical fibres, range
12 ... 480
Diameter over assembly
10.5 mm
Number of optical fibres
96
Inner sheath thickness
0.9 mm
Approximate weight
320 kg/km
Central strength member size
3.5 mm
Nominal outer sheath thickness
1.5 mm

Mechanical characteristics

Mechanical characteristics

Maximum pulling force by laying
2 kN
Maximum permanent tensile load
1 kN
Crush resistance (EN 187 000)
7 kN
Impact resistance (EN 187 000)
25 J

Usage characteristics

Usage characteristics

Installation type
Indoor/Outdoor
Operating temperature, range
-30 ... 70 °C
Ambient installation temperature, range
-15 ... 50 °C
Storage temperature, range
-40 ... 70 °C
Bending factor when installed
15 (xD)
Dynamic bending factor
20 (xD)
Index of reflexion cable
1.47
Index of reflexion fibre
1.468
Rodent protection
Corrugated steel tape
Smoke density
Low

Resources

Resources

Selling & delivery Information

The outer sheath of the cable is marked with cable type, manufacturer, identification number and meter marking.
The cable is delivered on wooden recyclable drums in lengths according to arrangement. The drum is marked with the cable type, length, rolling direction and installation information. Cable ends closed with end cap.

Declaration of Performance

  • Declaration of Performance n� : 1000129-SEGR
  • Certification Date : 6/8/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0366
  • Declared performance : Dca-s2,d2,a2

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close