Duct - GRHL Outdoor Loose tube Dry (12 - 288 fibres)

Products

GRHL-U-CDGNRV 12/T12 G657A1 S12

Nexans ref. 29033198-201-00 - Country ref. 4973060

  • Packaging: Drum (2000m)
  • Fiber optic type: SM (G657.A1)
  • Nominal outer diameter: 10.4 mm
  • Number of optical fibres: 12
  • Maximum pulling force by laying: 1.5 kN

 

GRHL-U-CDGNRV 24/T12 G657A1 S12

Nexans ref. 29033298-201-00 - Country ref. 4973070

  • Packaging: Drum (2000m)
  • Fiber optic type: SM (G657.A1)
  • Nominal outer diameter: 10.4 mm
  • Number of optical fibres: 24
  • Maximum pulling force by laying: 1.5 kN

 

GRHL-U-CDGNRV 48/T12 G657A1 S12

Nexans ref. 29033398-201-00 - Country ref. 4973080

  • Packaging: Drum (2000m)
  • Fiber optic type: SM (G657.A1)
  • Nominal outer diameter: 10.4 mm
  • Number of optical fibres: 48
  • Maximum pulling force by laying: 1.5 kN

 

GRHL-U-CDGNRV 72/T12 G657A1 S12

Nexans ref. 29061298-201-00

  • Packaging: Drum (2000m)
  • Fiber optic type: SM (G657.A1)
  • Nominal outer diameter: 10.4 mm
  • Number of optical fibres: 72
  • Maximum pulling force by laying: 1.5 kN

 

GRHL-U-CDGNRV 96/T12 G657A1 S12

Nexans ref. 29033498-201-00 - Country ref. 4973090

  • Packaging: Drum (2000m)
  • Fiber optic type: SM (G.652D)
  • Nominal outer diameter: 11.8 mm
  • Number of optical fibres: 96
  • Maximum pulling force by laying: 1.5 kN

 

GRHL-U-CDGNRV 144/T12 G657A1 S12

Nexans ref. 29061398-201-00

  • Packaging: Drum (2000m)
  • Fiber optic type: SM (G657.A1)
  • Nominal outer diameter: 15.0 mm
  • Number of optical fibres: 144
  • Maximum pulling force by laying: 1.5 kN

 

GRHL-U-CDGNRV 192/T12 G657A1 S12

Nexans ref. 29061498-201-00 - Country ref. 4970200

  • Packaging: Drum (2000m)
  • Fiber optic type: SM (G657.A1)
  • Nominal outer diameter: 15.4 mm
  • Number of optical fibres: 192
  • Maximum pulling force by laying: 1.5 kN

 

GRHL-U-CDGNRV 288/T12 G657A1 S12

Nexans ref. 29061698-201-00

  • Packaging: Drum (2000m)
  • Fiber optic type: SM (G657.A1)
  • Nominal outer diameter: 17.1 mm
  • Number of optical fibres: 288
  • Maximum pulling force by laying: 4 kN

 

Description

Description

Standards

  • International
    IEC 60793; IEC 60794; ITU-T Rec. G.650; ITU-T Rec. G.652

The cable type is longitudinally water-blocked and intended for outdoor use (in ducts). The design can incorporate 12 to 288 fibres in loose tubes with a diameter of 2,25 mm. The individually coloured fibres are tubed in groups of maximum 12, and stranded onto a central dielectric fibre reinforced strength member (FRP). The cable type is longitudinal water-blocked through the use of swellable tape and sheathed with halogen-free black polyethylene.

 

 

Quality and environmental management system

Certified according to ISO 9001, IRIS, ISO/TS 16949 and ISO 14001.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Construction type
Loose tube, SZ
Type of secondary protection
Loose tube
Outer sheath
PE
Sheath colour
Black
Material used for longitudinal water tightness
Swellable tape
Halogen free
Yes
Metal free
Yes
Length water tightness Tube
Vaseline
Strength member
Central FRP

Dimensional characteristics

Dimensional characteristics

Tube diameter
2.25 mm
Number of optical fibres, range
12 ... 288
Max. number of fibres per tube
12

Mechanical characteristics

Mechanical characteristics

Maximum permanent tensile load
0.75 kN
Crush resistance (EN 187 000)
3 kN
Impact resistance (EN 187 000)
15 J

Usage characteristics

Usage characteristics

Installation type
Outdoor - Duct
Operating temperature, range
-40 ... 70 °C
Ambient installation temperature, range
-15 ... 60 °C
Storage temperature, range
-40 ... 70 °C
Bending factor when installed
10 (xD)
Dynamic bending factor
15 (xD)

Resources

Resources

Selling & delivery Information

The outer sheath of the cable is marked with cable type, manufacturer, identification number and meter marking.
The cable is delivered on wooden recyclable drums in lengths according to arrangement. The drum is marked with the cable type, length, rolling direction and installation information. Cable ends closed with end cap.

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close